Transformer

Two magnetically coupled inductors that transfer energy between circuits while changing voltage and current levels. Used for AC voltage conversion, galvanic isolation, and impedance matching.

Properties​

PropertyDescriptionDefaultRange
Turns ratioPrimary-to-secondary turns ratio (n:1)10:10.01:1 – 1 000:1
Primary voltageRated primary winding voltage (V)230 V1 V – 10 000 V
Rated powerMaximum power the core can transfer (VA)50 VA1 VA – 100 000 VA
Coupling coefficientMagnetic coupling efficiency (0–1, where 1 is ideal)0.990.5 – 1.0

Simulation behavior​

Secondary voltage = primary voltage / turns ratio. Secondary current = primary current × turns ratio (conservation of power). Leakage inductance and core losses are modeled implicitly through the coupling coefficient — a value below 1 introduces magnetizing current and reduces the effective secondary voltage under load.

If power transferred through the core exceeds rated power, the transformer fails (open-circuit on both windings).

The transformer only operates with AC — a DC input produces no secondary output because there is no changing magnetic flux.

Tips​

  • A turns ratio of 1:1 creates a galvanically isolated version of the input signal — useful for eliminating ground loops between two circuits without changing voltage.
  • To step down 230 V AC to 12 V AC, set primary voltage to 230 V and turns ratio to approximately 19:1.
  • Keep the coupling coefficient at 0.99 for an ideal transformer model. Reduce it to 0.85–0.90 to model a loosely coupled or air-core transformer with significant leakage.